Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

STEP 4: Cage - Cage Cabinet

 Step 4.1

  1. Tools: 24mm wrench

  2. Because of weight we recommend being two persons to carry the Cage Cabinet to the cage

  3. Position it like shown in the picture, it will rest its weight on the handrail

  4. Now hold it to make sure it doesnt tip while attaching the bolts to the U-brackets

  5. Make sure the cabinet is firmly attached

Step 4.2 - General cable management

To avoid breakage of the connectors during operation, we use a knot (Halvstikk / dobbelt halvstikk) to secure the connectors. This knot is simple to add, and it makes sure that if a force is pulling the cable, the knot will take the beating, instead of the connectors.

The cable should not be bent more than a radius of 70mm.


This knot is used for: Power cable and both sensor cables.

image-20240205-154421.png


Step 4.3 - Power Cable

  • Use the knot from 4.2 before connecting to cabinet

  • Connect the 230VAC connector to port 5 inside the Cage Cabinet

  • Connect the other end to your Power-Supply-Cabinet

  • Use strips/rope/tape to attach the cable to the underside of the cage-handrail. We recommend to use strips on every vertical post, with some slack on the cable in between

  • No labels