In case of not being able to solve an issue or find the root cause - please contact Bluegrove CageEye tech support:

Observed problem

Reason

Solution

Bluegrove CageEye solution is offline

  1. Power outage on barge.

  2. No Internet.

  1. On site: check if the Bluegrove CageEye server has power.

  2. On the barge: Check that you have internet. Ex by going to https://fast.com/.

    1. Verify that the Bluegrove CageEye server/router is plugged into the switch/router. If it is, and there is still an issue: re-plug it.

No echograms / sensors offline

  1. Power outage on cage/s

  2. Network issue

  3. Placement issue

  1. Check that the cage has power by:

    1. See if there are lights on in the cage cabinet.

    2. Check fuses in the power distribution cabinet.

    3. Check the cable between CPU and the bulletcage antenna, try to reset it.

  2. Try to restart barge antenna

    1. Verify that the barge antenna points in the correct direction.

  3. Check that sensors are hanging correctly in the cage.

Cyclic pattern on echogram

Image Added
  1. Missing data from the accelerometer

  1. Power cycling the echosounder

No connection to the feeding system

  1. Power issue

  2. Network issue

  1. Check that feeding system is online and working properly.

  2. Contact your IT department and ask if the Bluegrove CageEye server and the feeding system are on the same subnet.

Missing signal from one echosounder.

  1. Damaged connector/cable.

  2. Internal error in Echosunder.

  1. Check if connector body is loose. If it is: inspect inside for damage.

    1. bilde-20241017-074513.pngImage Added
  2. Check cage-cabinet connector hole for damage/corrosion.

    1. bilde-20241017-074736.pngImage Added
  3. Check cable for damage.

    1. bilde-20241017-074857.pngImage Added