Feeding-system integrations and compatibility with CageEye

System supplier

Software

Compatible

 

Comment

Known limitations

Estimated Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

System supplier

Software

Compatible

 

Comment

Known limitations

Estimated Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

Fluctus AS

Fluctus

Fluctus version 6.9.5.8 and newer has demonstrated satisfactory uptime.

 

18 meals/ hour. 20s switching time.

ScaleAQ AS

FeedStation 2.0 Process API

Demonstrated satisfactory uptime.

Minimum and maximum intensity is driven by the amount of pellet per kilo.

17 meals/ hour. 30s switching time.

AKVA Group AS

AKVA Connect 2.13- 2.20.

 

Compatible when using Piscada OAP. Demonstrated satisfactory uptime.

 

17 meals/ hour. 30s switching time.

Uncompatible or untested feedingsystems

System supplier

Software

Compatible

Comment

Known limitations

Estimated Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

AKVA Group AS

AKVA Connect 4.1-4.3 series

with Piscada OAP.

In developement.

 

 

GroAqua

GroAqua

Untested.

 

 

Huber

Unknown

Untested.

 

 

AKVA Group AS

Akva Connect 2.x with Observe Marlin Systems by Observe Technologies LTD on

Tested in 2021 and 2022 and found not workable.

Very unstable. You can not read pressure levels or control blowers.

 

AKVA Group AS

AKVA Control 10

Discontinued. Proven poor stability makes us not recommend integrating with this feeding system.

Does not allow for blower control or blower readouts.

Can not start blower without also dosing feed.

Poor integration stability(ca 90%).

 

AKVA Group AS

AKVA Control 9

Discontinued. Hardware and software upgrade required to integrate.

 

 

Ocea Feedstation

Unknown

Discontinued. Acquired by ScaleAQ.

 

 

Vard Seaonics

Unknown

Software developed by Seaonics AS. No integration known.

 

 

GMT

Steinsvik legacy

Discontinued. Acquired by ScaleAQ.

 

 

ScaleAQ AS

Steinsvik legacy system

Untested. Requires a licence from ScaleAQ.

 

 

Laksesystemer

Unknown

Untested.

 

 

Betten feeders

Unknown

Untested.

 

 

Piscada Open Aquaculture Plattform(OAP) may be subcontracted to provide an integration layer by CageEye at the direction of the customer.