CageEye uses regular ethernet on the cage. The CageEye cabinet can be connected to any ethernet with DHCP.

Step 1. Verify that the RJ45 cable/socket have fully working network.

  1. If there is an EAP on site:

    1. Switch ethernet cables going into the EAP, if the EAP works the cable is ok.

  2. If no EAP is present, you can try any other equipment that uses ethernet, for example an IP-camera or laptop, if the device gets working network, the connection is ok.

Step 2. Connect to cage network.

1. Connecting to Akvasmart IP CAP / DIGITAL CAP

bilde-20240923-075428.png

At the customers instruction, CageEye can use the Ethernet connection in the CAP to facilitate communication between the cage and the barge.

Alternative

From CAP

Middle piece

To CageEye cabinet

1.

bilde-20240920-105525.png

Cable from cap with Connector:VS-08-RJ45-5-Q/IP67-BK (1658493)

Product photo Protective cover VS-SCRJ-PC

With Protective cap: S-SCRJ-PC (Art no: 1653757)

image-20240926-193544.png

Phoenix Contact VS-08-KU-IP67 Series RJ45 Coupler, Cat5e

bilde-20240920-105525.png

Cable to CageEye with Connector:VS-08-RJ45-5-Q/IP67-BK (1658493)

Product photo Protective cover VS-SCRJ-PC

With Protective cap: S-SCRJ-PC (Art no: 1653757)

Alternatives with re-terminating the ethernet cable from the CAP
If damaged, the life of the cable can be extended by replacing the connector.

image-20240924-122438.png

Female connector: Binder RD24 (Art no: 99 4218 110 07)

image-20240924-122220.png

With: Binder Protective Cap (Art no: 08 2300 000 000)

-

bilde-20240923-080240.png

Male connector: Binder RD24(Art no: 99 4217 110 07)

image-20240924-121527.png

With: Binder Protective Cap (Art no: 08 2299 000 000)

3

Female connector:

-

C016 30H006 110 12

Male connector: Amphenol Ecomate (Art no: C016 30H006 110 12)

C016 00U000 010 12

With: Protective Cap (Art no: C016 00U000 010 12)

Wiring scheme on Ethernet cable coming from the CAP

bilde-20240923-080825.pngimage-20240926-194144.pngimage-20240926-194232.png



Further reading

5. The CageEye Cage Cabinet interface

The cage cabinet has two network interfaces. this connector for ethernet

In the CageEye cabinet

Compatible connector on cabinet side.

Compatible cable

image-20240926-170035.png


Panel mount: RD24 Female panel mount connector(09 4220 00 07)

bilde-20240923-080240.png

Male connector: Binder RD24(Art no: 99 4217 110 07)

image-20240924-121527.png

With: Binder Protective Cap (Art no: 08 2299 000 000)

Outdoor shielded Cat5e, Cat6 or Cat6.

Must have outer diameter of Ø8 to be compatible with both:
VS-08-RJ45-5-Q/IP67-BK (1658493)

Binder RD24(Art no: 99 4217 110 07)


How to assemble Binder RD24 Connectors

image-20240508-121207.png

Contact arrangement for Binder RD24 or Amphenol Ecomate.

image-20240923-151344.pngimage-20240508-113934.png

Cat cable termination

Connector Pin #

image-20240923-151344.png

Wire Color

Rj45 pin number

bilde-20240923-080825.png

Cable Pair(if colors differ)

1

White/Orange

1

2

2

Orange

2

2

3

White/Green

3

3

4

Green

6

3

5

White/Brown AND Brown

7-8

4

6

White/Blue AND Blue

4-5

1

Earth

Shield

Troubleshooting

Symptom

Cause

Remedy

bilde-20240924-152357.png

  1. Loose connector casing.

  2. To small cable used.

  1. If wire does not have water in it or corrosion damage: You can replace the connector.

  2. If too small wire is used: replace wire.

Appendix

AKVA Group Winch cable pinout on Amphenol Ecomate.

This cable pinout is NOT compatible with CageEye cabinets.

Connector Pin #

image-20240923-151344.png

Wire Color

Rj45 pin number

bilde-20240923-080825.png

1

?

?

2

?

?

3

Green

6

4

White brown

7

5

Brown

8

6

White green

3

Earth

Shield