CageEye uses regular ethernet on the cage. The CageEye cabinet can be connected to any ethernet with dhcp.
1. Connecting to Akvasmart IP CAP / DIGITAL CAP
At the customers instruction, CageEye can use the Ethernet connection in the CAP to facilitate communication between the cage and the barge.
Alternatives for connecting to the CAP
Alternative | From CAP | Middle piece | To CageEye cabinet |
---|---|---|---|
1. | Cable from cap with Connector:VS-08-RJ45-5-Q/IP67-BK (1658493) With Protective cap: S-SCRJ-PC (Art no: 1653757) | Phoenix contact Female Female contact. | Cable to CageEye with Connector:VS-08-RJ45-5-Q/IP67-BK (1658493) With Protective cap: S-SCRJ-PC (Art no: 1653757) |
Alternatives with re-terminating the ethernet cable from the CAP | |||
Female connector: Binder RD24 (Art no: 99 4218 110 07) | Male connector: Binder RD24(Art no: 99 4217 110 07) | ||
3 | Female connector: |
Wiring scheme on Ethernet cable coming from the CAP
Further reading
5. The CageEye Cage Cabinet interface
The cage cabinet has two network interfaces. this connector for ethernet
In the CageEye cabinet | Compatible connector |
---|---|
TODO: | Female connector: Binder RD24 (Art no: 99 4218 110 07) |
How to assemble Binder RD24 Connectors
Contact arrangement for Binder RD24 or Amphenol Ecomate.
Cat cable termination | |||
---|---|---|---|
Connector Pin # | Wire Color | Rj45 pin number | Cable Pair(if colors differ) |
1 | White/Orange | 1 | 2 |
2 | Orange | 2 | 2 |
3 | White/Green | 3 | 3 |
4 | Green | 6 | 3 |
5 | White/Brown AND Brown | 7-8 | 4 |
6 | White/Blue AND Blue | 4-5 | 1 |
Earth | Shield |
Troubleshooting
Symptom | Cause | Remedy |
---|---|---|