CageEye uses regular marine ethernet cables on the cage. The cabinet can be connected to ethernet with the correct connector.

1. Connecting to Akvasmart IP CAP / DIGITAL CAP

bilde-20240923-075428.png

At the customers instruction, CageEye can use the Ethernet connection in the CAP to facilitate communication between the cages and the barge network.

Alternatives for connecting to the CAP

Alternative

From CAP

Middle piece

To CageEye cabinet

1 Default.

bilde-20240920-105525.png

Phoenix contact Female Female contact.

bilde-20240920-105525.png
  1. Reterminate the Cat6 cable

Cut the cable and install a
Binder RD24

Male

Binder 99421711007

Dust cap: 734-5060

Female

Binder: 99421811007

bilde-20240923-080240.png

3

Amphenol ecomate

Wiring scheme on Ethernet cable.

bilde-20240923-080825.png

For reference:

5. The CageEye Cage Cabinet interface

The cage cabinet has this connector for ethernet.

image-20240508-112432.pngimage-20240508-120919.png

Note. The dust cap must be used at all times.

1.1 Cable connector for cage cabinet networking

Use the connector: Binder RD24(Art no: 99 4217 110 07)

With RD24 - Protective cap: Binder Protective Cap (Art no: 08 2299 000 000)

image-20240508-121216.pngimage-20240508-121207.pngimage-20240508-121154.png

The dust cap must be used at all times.

image-20240508-121346.png

Contact arrangement

image-20240923-151344.png

image-20240508-113934.png

Cat cable termination

Pin #

Color

Cable Pair(if colors differ)

1

White/Orange

2

2

Orange

2

3

White/Green

3

4

Green

3

5

White/Brown AND Brown

4

6

White/Blue AND Blue

1

Earth

Shield