CageEye uses regular marine ethernet cables on the cage. The cabinet can be connected to ethernet with the correct connector.

1. Connecting to Akvasmart IP CAP / DIGITAL CAP

bilde-20240920-101123.png

Inside the AKVA cap there is a network-switch. At the customers instruction, CageEye can use this switch to get connection between the cages and the barge network.

55EF3032-E8C0-4F57-8218-C7377FB3C8EF_1_105_c-20240703-141306.jpeg

Connect to an ethernet cable from the CAP:

bilde-20240923-075428.png

Alternative

From CAP

1

bilde-20240920-105525.png

Middle piece

bilde-20240920-105525.png

Phoenix contact VS-08-RJ45-5-Q/IP67-BK - RJ45 connector

2

Binder RD24

bilde-20240923-080240.png

3

Amphenol ecomate

bilde-20240923-080825.png

Cables coming from the Switch.

Alternative 2 - Connect to a free port cable from the CAP bottom section:

For reference:

5. The CageEye Cage Cabinet interface

The cage cabinet has this connector for ethernet.

image-20240508-112432.pngimage-20240508-111752.pngimage-20240508-120919.png

Note. The dust cap must be used at all times.

1.1 Cable connector for cage cabinet networking

Use the connector: Binder RD24(Art no: 99 4217 110 07)

With RD24 - Protective cap: Binder Protective Cap (Art no: 08 2299 000 000)

image-20240508-121216.pngimage-20240508-121207.pngimage-20240508-121154.png

The dust cap must be used at all times.

image-20240508-121346.png

Contact arrangement (Plug-in side)

image-20240508-113934.png

Cat cable termination

Pin #

Color

Cable Pair(if colors differ)

1

White/Orange

2

2

Orange

2

3

White/Green

3

4

Green

3

5

White/Brown AND Brown

4

6

White/Blue AND Blue

1

Earth

Shield