System supplier

Software

Compatible

Comment

Known limitations

Estimated Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

Fluctus AS

Fluctus

(tick)

Fluctus version 6.9.5.8 and newer has demonstrated satisfactory uptime.

18 meals/ hour. 20s switching time.

ScaleAQ AS

FeedStation 2.0 Process API

(tick)

Demonstrated satisfactory uptime.

Minimum and maximum intensity is driven by the amount of pellet per kilo.

17 meals/ hour. 30s switching time.

AKVA Group AS

AKVA Connect 2.13- 2.20.

(tick)

Compatible when using Piscada OAP.

17 meals/ hour. 30s switching time.

Uncompatible or untested feedingsystems

System supplier

Software

Compatible

Comment

Known limitations

Estimated Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

AKVA Group AS

Observe Marlin Systems by Observe Technologies LTD on Akva Connect 2.x

❌

Compatible with Piscada OAP. Add on to AKVA connect 2.20

Very unstable.

You can not read pressure levels or control blowers.

AKVA Group AS

AKVA Connect 4.1-4.3 series

(tick)

via Piscada

In developement.

AKVA Group AS

AKVA Control 10

🟑 Limited compatibility with OAP.

Proven poor stability makes us not recommend integrating with this feeding system. Can be compatible with Piscada OAP. Requires use of an β€œAKVA connector” license key.

Does not allow for blower control or blower readouts.

Can not start blower without also dosing feed.

Poor integration stability(ca 90%).

AKVA Group AS

AKVA Control 9

❌

Hardware and software upgrade required to integrate.

Piscada

Open Aquaculture Plattform(OAP)

❌

Not a feeding system. Piscada is specialized in integrating industrial systems.

Ocea Feedstation

Unknown

🟑 Limited compatibility with OAP.

Untested. Discontinued. Aquired by ScaleAQ.

Vard Seaonics

Unknown

❌

Software developed by Seaonics AS. Open to integrating but has not done so to date.

GMT

Steinsvik legacy

❌

Discontinued. Aquired by ScaleAQ.

ScaleAQ AS

Steinsvik legacy system

🟑 Limited compatibility with OAP.

Untested. Requires a licence from ScaleAQ.

AKVA Group AS

FishTalk Control

❌

Not a feeding system. Extensively used ERP.

JTElectric

JTElectric

❔

Untested

Laksesystemer

Unknown

🟑 Limited compatibility with OAP.

Untested

Betten feeders

Unknown

🟑 Limited compatibility with OAP.

Untested

Huber

Unknown

❔

Untested