In short
Stable power on the cage and barge
Stable internet
Detailed requirements
These requirements define the optimal environment for Bluegrove systems. If any of the requirements are not met the Bluegrove service will be impacted as described in Impact of infrastructure loss at the end of this page.
Related documents:
Environmental parameter limitations: EN/NO/ES Environmental parameters limtiations / Grenseverdier for bruk / Límites de exposición ambiental
1. Physical requirements
1.1 Cage requirements
Minimum 15m deep nets.
1.2 Limitations in use/performance with other components
Main components
Component | Problem | Solution |
---|---|---|
Cage: Hvalpsund HD500NG | Conflict between the top bracket fixture and the handrail post. | Use ratchet straps or rope to tie the top part of the bracket to the pole. |
Extra equipment
Component | Problem | Solution / Løsning |
---|---|---|
Aeration devices. Sold under names like(Midt-Norsk ring, Turbolift etc) | The echosounder picks up the bubbles and creates a noisy image. | None. Echosounders are not compatible with aeration rings. |
Aside from these components, the equipment is compatible with any other component that is not directly interfering with it.
2 Power Requirements
2.1 Power at barge
The CageEye system requires 2 kW @ 230V 50hz at the barge.
The system complies with the international EMC standards:
IEC/EN 60950-1
IEC/EN 61000-3-3
IEC/EN 61000-6-1
IEC/EN 61000-6-3
In case of power source problems such as noise, spikes, brownouts and blackouts, an Online UPS system needs to be installed to accommodate continuous power stability and availability.
2.2 Power at cage
The CageEye system requires 60 W @ 230V 50hz outlet at the cage.
Estimated continuous power requirements for all sensor devices in cage: 60 W
Estimated maximum power consumption in the future, incl. UPS, camera, etc.: 500 W
Refer to suppliers technical datasheets for exact requirements.
In case of power source problems such as noise, spikes, brownouts and blackouts, an Online UPS system needs to be installed to accommodate continuous power stability and availability.
3. Network Requirements
3.1 Barge local network
Ethernet 802.3ab compatible connection available for all barge services.
Required network performance to provide optimal services:
Service | Bandwidth | Uptime | Latency | Packet Loss | Jitter |
Network services on barge | 1 Gbit | 100% | 2 ms | 0 | 15% |
3.2: Cage to barge network
Clear line of sight from barge roof to cages. Ethernet 802.3ab compatible connection available for all cage services. Required network performance to provide optimal services:
Service | Bandwidth | Uptime | Latency | Packet Loss | Jitter |
Network services on cage | 200 Mbit | 100% | 5 ms | 0 | 15% |
Bandwidth, uptime, latency, packet loss and jitter between devices on barge network and devices on cage.
3.3: Internet
Services dependent on dedicated internet connection bandwidth with minimum requirements:
Service | Upload | Uptime | Latency | Packet Loss | Jitter |
Analytics and reports | 1 Mbps | 90% | 150 ms | 5% over 10 minutes | 15% |
Cloud data API | 1 Mbps | 90% | 150 ms | 5% over 10 minutes | 15% |
Feeding algorithms | 1 Mbps | 90% | 150ms | 5% over 10 minutes | 15% |
Upload bandwidth, uptime, latency, packet loss and jitter between devices on the barge network and Bluegrove Cloud.
If the internet subscription has a monthly limit for traffic we need 100 GB a Month.
Ports used by Bluegrove
Type | Port | Used for | Traffic |
TCP | 1194 | VPN for access to Bluegrove cloud. | Incoming and outgoing |
TCP | 80 | HTTP outgoing for connection to API. Eg environmental data. HTTP incoming to be able to connect from the feed center. | Incoming and outgoing |
TCP | 443 | HTTP outgoing for connection to API. Eg environmental data. HTTP incoming to be able to connect from the feed center. | Incoming and outgoing |
3.4: Barge to Feeding Operations Center network
Services dependant on dedicated network connection bandwidth with minimum requirements:
Service | Upload | Uptime | Latency | Packet Loss | Jitter |
Feeding assistant (remote, without video) | 5 Mbps | 100% | 150 ms | 1% over 10 minutes | 15% |
Feeding assistant (remote, with video) | 30 Mbps | 100% | 150 ms | 1% over 10 minutes | 15% |
Upload bandwidth, uptime, latency, packet loss and jitter between devices on the barge network and the Feeding Operations Center.
4 Integration Requirements
4.1 Operational feeding system integration
The customer must to provide Bluegrove with an integration to his feeding system. Bluegrove maintains this list of compatible feeding-systems: Feeding-system integrations and compatibility with Bluegrove
4.1.1 General feeding system integration requirements and definitions
5. Barge and feeding system
5.1. User terminal at barge (PC with UI)
PC with at least 1 display screen per 12 cages: Minimum 24”, 1920x1080 resolution
Mouse/Keyboard
Chrome Browser
5.2. User terminal remote (PC with UI)
Optional remote PC with at least 1 display screen per 12 cages: Minimum 24”, 1920x1080 resolution
Mouse/Keyboard
CageEye VPN Installed
Chrome Browser
5.3. Operational feeding system
The blowers, dosing, changers, piping, feed spreaders need to be in working condition.
5.4. Farm environmental sensors - Required for analytics and reporting
Sensors at farm with API.
Oxygen
Salinity
Temperature
Water-current
Weather
6. Machine vision for pellet detection and health indicators.
6.1. RTSP streams
RTSP streams from the camera available on the network we have access to.
Relation between RTSP stream and cage
7. Impact of infrastructure loss
Impact category | Example effect |
Emergency | Immediately stops service |
Severe | Critically impacts service/stops service within one day |
Moderate | Impacts service/partial loss of service |
Minor | Reduced convenience |
Requirement | Effect on service | Suggested Solution | |
Barge and feeding system | 1.1 Power at barge | Emergency | 2KW Online UPS |
2.1. Barge local network | Emergency | Managed network service including ubiquiti router, network cables, installation and configuration. | |
3.1. Operational feeding system | Emergency | ||
4.2. User terminal at barge (PC with UI) | Severe | ||
4.1. Farm environmental sensors | Minor | ||
Remote | 2.3a. Internet | Severe | Primary and redundancy options:
|
4.3. User terminal remote (PC with UI) | Severe |