Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

View file
nameUK Akvasmart CAP Installation and maintenance manual.pdf
View file
nameNO Cage Access Point BrukerhÄndbok Rev A 2021_AKVA group.pdf

Troubleshooting

Symptom

Cause

Remedy

bilde-20240924-152357.pngImage Added

  1. Loose connector casing.

  2. To small cable used.

  1. If wire does not have water in it or corrosion damage: You can replace the connector.

  2. If too small wire is used: replace wire.

Appendix

5. The CageEye Cage Cabinet interface

...

Cat cable termination

Connector Pin #

image-20240923-151344.png

Wire Color

Rj45 pin number

bilde-20240923-080825.png

Cable Pair(if colors differ)

1

White/Orange

1

2

2

Orange

2

2

3

White/Green

3

3

4

Green

6

3

5

White/Brown AND Brown

7-8

4

6

White/Blue AND Blue

4-5

1

Earth

Shield

Troubleshooting

...

Symptom

...

Cause

...

Remedy

bilde-20240924-152357.pngImage Removed

...

  1. Loose connector casing.

  2. To small cable used.

...

  1. If wire does not have water in it or corrosion damage: You can replace the connector.

  2. If too small wire is used: replace wire.

...

AKVA Group Winch cable pinout on Amphenol Ecomate.

...