At the customers instruction, CageEye can use the Ethernet connection in the CAP to facilitate communication between the cages and the barge network.

Alternatives for connecting to the CAP

Alternative

From CAP

Middle piece

To CageEye cabinet

1 Default.

bilde-20240920-105525.png

With cap:

Phoenix contact Female Female contact.

bilde-20240920-105525.png

  1. Reterminate the Cat6 cable

Cut the cable and install a
Binder RD24

MaleWith cap:

Alternatives with re terminating the ethernet cable.
Sometimes the Phoenix contact is damaged by corrosion. The life of the cable can then be extended by replacing the connector.

Female

Binder: 99421811007

bilde-20240923-080240.pngImage Added

Male connector:
Binder 99421711007
Dust cap: 734-5060

Female

Binder: 99421811007

bilde-20240923-080240.pngImage Removed

3

Amphenol ecomate

Wiring scheme on Ethernet cable

...

...

coming from the CAP

T568B

...

Further reading.

View file
nameUK Akvasmart CAP Installation and maintenance manual.pdf
View file
nameNO Cage Access Point BrukerhÄndbok Rev A 2021_AKVA group.pdf

...

Cat cable termination

Pin #

Color

Cable Pair(if colors differ)

1

White/Orange

2

2

Orange

2

3

White/Green

3

4

Green

3

5

White/Brown AND Brown

4

6

White/Blue AND Blue

1

Earth

Shield

Troubleshooting

Symptom

Cause

Remedy