CageEye uses regular marine ethernet cables on the cage. The cabinet can be connected to ethernet with the correct connector.
1. Connecting to Akvasmart IP CAP / DIGITAL CAP
At the customers instruction, CageEye can use the Ethernet connection in the CAP to facilitate communication between the cages and the barge.
Alternatives for connecting to the CAP
Alternative | From CAP | Middle piece | To CageEye cabinet |
---|---|---|---|
1. | With cap: | Phoenix contact Female Female contact. | With cap: |
Alternatives with re terminating the ethernet cable. | |||
Female Binder: 99421811007 | Male connector: | ||
3 | Amphenol ecomate |
Wiring scheme on Ethernet cable coming from the CAP
T568B
Further reading.
5. The CageEye Cage Cabinet interface
The cage cabinet has this connector for ethernet.
Note. The dust cap must be used at all times.
1.1 Cable connector for cage cabinet networking
Use the connector: Binder RD24(Art no: 99 4217 110 07)
With RD24 - Protective cap: Binder Protective Cap (Art no: 08 2299 000 000)
The dust cap must be used at all times.
Contact arrangement
Cat cable termination | ||
---|---|---|
Pin # | Color | Cable Pair(if colors differ) |
1 | White/Orange | 2 |
2 | Orange | 2 |
3 | White/Green | 3 |
4 | Green | 3 |
5 | White/Brown AND Brown | 4 |
6 | White/Blue AND Blue | 1 |
Earth | Shield |
Troubleshooting
Symptom | Cause | Remedy |
---|---|---|