About the requirements

These requirements define the optimal environment for Bluegrove systems. If any of the requirements are not met the Bluegrove service will be impacted as described in Impact of infrastructure loss at the end of this page.

Power Requirements

1.1 Power at barge

The CageEye system requires 2 kW @ 230V 50hz at the barge.

The system complies with the international EMC standards:

In case of power source problems such as noise, spikes, brownouts and blackouts, an Online UPS system needs to be installed to accommodate continuous power stability and availability.

1.2 Power at cage

The CageEye system requires 60 W @ 230V 50hz outlet at the cage.
Estimated continuous power requirements for all sensor devices in cage: 60 W
Estimated maximum power consumption in the future, incl. UPS, camera, etc.: 500 W
Refer to suppliers technical datasheets for exact requirements.

In case of power source problems such as noise, spikes, brownouts and blackouts, an Online UPS system needs to be installed to accommodate continuous power stability and availability.

2. Network Requirements

2.1 Barge local network

Ethernet 802.3ab compatible connection available for all barge services.
Required network performance to provide optimal services:

Service

Bandwidth

Uptime

Latency

Packet Loss

Jitter

Network services on barge

1 Gbit

100%

2 ms

0

15%

2.2: Cage to barge network

Ethernet 802.3ab compatible connection available for all cage services. Required network performance to provide optimal services:

Service

Bandwidth

Uptime

Latency

Packet Loss

Jitter

Network services on cage

200 Mbit

100%

5 ms

0

15%

2.3a: Internet

Services dependent on dedicated internet connection bandwidth with minimum requirements:

Service

Upload

Uptime

Latency

Packet Loss

Jitter

Analytics and reports

1 Mbps

90%

150 ms

5% over 10 minutes

15%

Cloud data API

1 Mbps

90%

150 ms

5% over 10 minutes

15%

Feeding algorithms

1 Mbps

90%

150ms

5% over 10 minutes

15%

Ports used by Bluegrove

Type

Port

Used for

Traffic

TCP

1194

VPN for access to Bluegrove cloud.

Incoming and outgoing

TCP

80

HTTP outgoing for connection to API. Eg environmental data.

HTTP incoming to be able to connect from the feed center.

Incoming and outgoing

TCP

443

HTTP outgoing for connection to API. Eg environmental data.

HTTP incoming to be able to connect from the feed center.

Incoming and outgoing

6b: Barge to Feeding Operations Center network

Services dependant on dedicated network connection bandwidth with minimum requirements:

Service

Upload

Uptime

Latency

Packet Loss

Jitter

Feeding assistant (remote, without video)

5 Mbps

100%

150 ms

1% over 10 minutes

15%

Feeding assistant (remote, with video)

30 Mbps

100%

150 ms

1% over 10 minutes

15%

Integration Requirements

3.1 Feeding system

Feeding system requirements version 0.0.6. Bluegrove maintains a list of feedingsystems, their compatibility status; and known limitations.

This section defines general requirements for controlling a feeding system for sea-based and land based aquaculture.

Intention

Enable the fish farmer to:

Definition

Sketch of feeding machinery

Out of scope features

Required functionality:

Lack of functionality for this functionality results in 

4. Barge and feeding system

4.1. User terminal at barge (PC with UI)

4.2. User terminal remote (PC with UI)

4.3. Operational feeding system

The blowers, dosing, changers, piping, feed spreaders need to be in working condition.

4.4. Farm environmental sensors - Required for analytics and reporting

Sensors at farm: 

5. Machine vision for pellet detection and health indicators.

5.1. RTSP streams

6. Impact of infrastructure loss

Impact category

Example effect

Emergency

Immediately stops service

Severe

Critically impacts service/stops service within one day

Moderate

Impacts service/partial loss of service

Minor

Reduced convenience

Requirement

Effect on service

Suggested Solution

Barge and feeding system

1.1 Power at barge

Emergency

2KW Online UPS

2.1. Barge local network

Emergency

Managed network service including ubiquiti router, network cables, installation and configuration.

3.1. Operational feeding system

Emergency

4.2. User terminal at barge (PC with UI)

Severe

4.1. Farm environmental sensors

Minor

Remote

2.3a. Internet

Severe

Primary and redundancy options:

  1. Point-to-point ethernet backhaul

  2. Satellite network

  3. 4G mobile network

4.3. User terminal remote (PC with UI)

Severe