Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 13 Next »

CageEye uses regular marine ethernet cables on the cage. The cabinet can be connected to ethernet with the correct connector.

1. The CageEye Cage Cabinet interface

The cage cabinet has this connector for ethernet.

image-20240508-112432.pngimage-20240508-111752.pngimage-20240508-120919.png

Note. The dust cap must be used at all times.

1.1 Cable connector for cage cabinet networking

Use the connector: Binder RD24(Art no: 99 4217 110 07)

With RD24 - Protective cap: Binder Protective Cap (Art no: 08 2299 000 000)

image-20240508-121216.pngimage-20240508-121207.pngimage-20240508-121154.png

The dust cap must be used at all times.

image-20240508-121346.png

Contact arrangement (Plug-in side)

image-20240508-113934.png

Cat cable termination

Pin #

Color

Cable Pair(if colors differ)

1

White/Orange

2

2

Orange

2

3

White/Green

3

4

Green

3

5

White/Brown AND Brown

4

6

White/Blue AND Blue

1

Earth

Shield

2. Connecting to the network in AKVA Group CAP

Inside the AKVA cap there is a regular switch. At the customers instruction, CageEye can connect to this switch to get access to the barge network.

55EF3032-E8C0-4F57-8218-C7377FB3C8EF_1_105_c-20240703-141306.jpeg

Alternative 1 - Connect to an unused cable from the switch(green):

Alternative 2 - Connect to a free port cable from the CAP bottom section:


  • No labels