Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 4 Next »

CageEye uses regular marine ethernet cables on the cage. To connect the cage you terminate the network cable to interface with the Cage Cabinet interface.

CageEye Cage Cabinet interface

image-20240508-112432.pngimage-20240508-111752.png

Note. A dust cap must be used at all times at sea.

https://www.binder-usa.com/us-en/products/accessories/protecting-cap/08-2673-000-000-rd24-protection-cap-for-flange-socket-series-692-693

Cable connector for cage cabinet networking

Use [connector] https://www.binder-connector.com/en/products/power-connectors/rd24-power/99-4217-14-07-rd24-male-cable-connector-contacts-6-pe-100-120-mm-unshielded-screw-clamp-ip67-ul-esti-vde-pg-135

https://www.binder-connector.com/en/products/power-connectors/rd24-power/99-4217-110-07-rd24-male-cable-connector-contacts-6-pe-80-100-mm-unshielded-screw-clamp-ip67-ul-esti-vde-pg-11

Contact arrangement (Plug-in side)

image-20240508-113934.png

Cat cable termination

Pin #

Color

Cable Pair(if colors differ)

1

White/Orange

2

2

Orange

2

3

White/Green

3

4

Green

3

5

White/Brown AND Brown

4

6

White/Blue AND Blue

1

Earth

Shield

A dust cap must be used at all times. https://www.binder-connector.com/en/products/accessories/protecting-cap/08-2299-000-000-rd24-protective-cap-for-cable-connector-series-692-693

  • No labels