Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »

CageEye uses regular marine ethernet cables on the cage. The cabinet can be connected to a regular ethernet with the correct connector.

CageEye Cage Cabinet interface

image-20240508-112432.pngimage-20240508-111752.pngimage-20240508-120919.png

Note. The dust cap must be used at all times.

Cable connector for cage cabinet networking

Use the connector: Binder RD24(Art no: 99 4217 14 07)

image-20240508-121216.png

image-20240508-121207.png

image-20240508-121154.png

A dust cap must be used at all times

image-20240508-121346.png

Contact arrangement (Plug-in side)

image-20240508-113934.png

Cat cable termination

Pin #

Color

Cable Pair(if colors differ)

1

White/Orange

2

2

Orange

2

3

White/Green

3

4

Green

3

5

White/Brown AND Brown

4

6

White/Blue AND Blue

1

Earth

Shield