System supplier

Software

Compatible

Comment

Known limitations

Switching time between cages
(Time from blowing feed into one cage into the next)

Can you get fish count and average weigh through API?

Can you get pellet size through API?

[Internal] Link to detailed documentation.

Fluctus AS

Fluctus

(tick)

Fluctus version 6.9.5.8 and newer has demonstrated satisfactory uptime.

Yes

Yes

Fluctus

ScaleAQ AS

FeedStation 2.0 Process API

(tick)

Demonstrated satisfactory uptime.

Minimum and maximum intensity is driven by the amount of pellet per kilo.

Yes, with the additional feeding Data API.

ScaleAQ

AKVA Group AS

AKVA Connect 2.20

(tick)

via Piscada

Compatible with Piscada OAP.

/wiki/spaces/TRB/pages/637108308

AKVA Group AS

AKVA Connect 2.13-2.17 series

(tick)

via Piscada

Compatible with Piscada OAP. Good trackrecord on stability.

No

No

/wiki/spaces/TRB/pages/637108308

Uncompatible or untested feedingsystems

System supplier

Software

Compatible

Comment

Known limitations

Swithcing time between cages

Can you get fish count and average weigh through API?

Can you get pellet size through API?

[Internal] Link to detailed documentation.

AKVA Group AS

Observe Marlin Systems by Observe Technologies LTD

🟑 Limited compatibility with OAP.

Compatible with Piscada OAP. Add on to AKVA connect 2.20

You can not control blowers.

/wiki/spaces/TRB/pages/937230351

AKVA Group AS

AKVA Connect 4.1-4.3 series

(tick)

via Piscada

In developement.

/wiki/spaces/TRB/pages/637108308

AKVA Group AS

AKVA Control 10

🟑 Limited compatibility with OAP.

Proven poor stability makes us not recommend integrating with this feeding system. Can be compatible with Piscada OAP. Requires use of an β€œAKVA connector” license key.

Does not allow for blower control or blower readouts.

Can not start blower without also dosing feed.

Poor integration stability(ca 90%).

/wiki/spaces/TRB/pages/637108308

AKVA Group AS

AKVA Control 9

❌

Hardware and software upgrade required to integrate.

/wiki/spaces/TRB/pages/637108308

Piscada

Open Aquaculture Plattform(OAP)

❌

Not a feeding system. Piscada is specialized in integrating industrial systems.

Yes

No

Piscada

Ocea Feedstation

Unknown

🟑 Limited compatibility with OAP.

Untested. Discontinued. Aquired by ScaleAQ.

Vard Seaonics

Unknown

❌

Software developed by Seaonics AS. Open to integrating but has not done so to date.

GMT

Steinsvik legacy

❌

Discontinued. Aquired by ScaleAQ.

ScaleAQ AS

Steinsvik legacy system

🟑 Limited compatibility with OAP.

Untested. Requires a licence from ScaleAQ.

Yes

No

AKVA Group AS

FishTalk Control

❌

Not a feeding system. Extensively used ERP.

JTElectric

JTElectric

❔

Untested

Yes

No

Laksesystemer

Unknown

🟑 Limited compatibility with OAP.

Untested

Betten feeders

Unknown

🟑 Limited compatibility with OAP.

Untested

Huber

Unknown

❔

Untested

  • No labels