The system complies with the international EMC standards: IEC/EN 60950-1, IEC/EN 61000-3-3, IEC/EN 61000-6-1 and IEC/EN 61000-6-3.

A ground fault circuit interrupter must be used.

In case of power source problems such as noise, spikes, brownouts and blackouts, a UPS system needs to be installed to accommodate continuous power stability and availability.

...

Estimated continuous power requirements for all sensor devices in cage: 60 W
Estimated maximum power consumption in the future 500 W.
The CageEye system requires 60 W @ 230V 50hz outlet at the cage. The power supply must have a C16A or a D16A circuit breaker. A ground fault circuit interrupter must be used.

Info

What happens if the requirement is not met:

Service stops as soon as the power is interrupted. This is mitigated by using a UPS(battery).

...