Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

System supplier

Software

Compatible

Comment

Known limitations

Time between the meals
Time from the last pellet is dosed in one cage; until it doses the first pellet into the next cage. Default pre-/post-flushing - 120 seconds

Max number of meals per hour
Given switching time [X]s. Assuming 60s meals.

Can you get fish count and average weigh through API?

Can you get pellet size through API?

Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

[Internal] Link to detailed documentation.

Fluctus AS

Fluctus

(tick)

Fluctus version 6.9.5.8 and newer has demonstrated satisfactory uptime.20s (140s in total)

18 meals (200s every in total) / hour

Yes

Yes

Fluctus

. 20s switching time.

/wiki/spaces/SA/pages/554861026

ScaleAQ AS

FeedStation 2.0 Process API

(tick)

Demonstrated satisfactory uptime.

Minimum and maximum intensity is driven by the amount of pellet per kilo.30s (150s in total)

17 meals (200s every in total) / hour

Yes, with the additional feeding Data API.

ScaleAQ / hour. 30s switching time.

/wiki/spaces/SA/pages/554664303

AKVA Group AS

AKVA Connect 2.20

(tick)

via Piscada

Compatible with when using Piscada OAP.30s (150s in total)

17 meals (200s every in total) / hour. 30s switching time.

/wiki/spaces/TRB/pages/637108308

AKVA Group AS

AKVA Connect 2.13-2.17 series

(tick)via Piscada

Compatible with when using Piscada OAP. Good trackrecord on stability.

30s (150s in total)

17 meals (200s every in total) / hour

No

No

. 30s switching time.

/wiki/spaces/TRB/pages/637108308

...

System supplier

Software

Compatible

Comment

Known limitations

Swithcing time between cages

Can you get fish count and average weigh through API?

Can you get pellet size through API?

Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

[Internal] Link to detailed documentation.

AKVA Group AS

Observe Marlin Systems by Observe Technologies LTD

🟡 Limited compatibility with OAP.

Compatible with Piscada OAP. Add on to AKVA connect 2.20

You can not control blowers.

/wiki/spaces/TRB/pages/937230351

AKVA Group AS

AKVA Connect 4.1-4.3 series

(tick)

via Piscada

In developement.

/wiki/spaces/TRB/pages/637108308

AKVA Group AS

AKVA Control 10

🟡 Limited compatibility with OAP.

Proven poor stability makes us not recommend integrating with this feeding system. Can be compatible with Piscada OAP. Requires use of an “AKVA connector” license key.

Does not allow for blower control or blower readouts.

Can not start blower without also dosing feed.

Poor integration stability(ca 90%).

/wiki/spaces/TRB/pages/637108308

AKVA Group AS

AKVA Control 9

Hardware and software upgrade required to integrate.

/wiki/spaces/TRB/pages/637108308

Piscada

Open Aquaculture Plattform(OAP)

Not a feeding system. Piscada is specialized in integrating industrial systems.

Yes

No

Piscada

/wiki/spaces/TRB/pages/553320885

Ocea Feedstation

Unknown

🟡 Limited compatibility with OAP.

Untested. Discontinued. Aquired by ScaleAQ.

Vard Seaonics

Unknown

Software developed by Seaonics AS. Open to integrating but has not done so to date.

GMT

Steinsvik legacy

Discontinued. Aquired by ScaleAQ.

ScaleAQ AS

Steinsvik legacy system

🟡 Limited compatibility with OAP.

Untested. Requires a licence from ScaleAQ.

Yes

No

AKVA Group AS

FishTalk Control

Not a feeding system. Extensively used ERP.

JTElectric

JTElectric

Untested

Yes

No

Laksesystemer

Unknown

🟡 Limited compatibility with OAP.

Untested

Betten feeders

Unknown

🟡 Limited compatibility with OAP.

Untested

Huber

Unknown

Untested