System supplier | Software | Compatible | Comment | Known limitations | Time between the meals | Max number of meals per hour | Can you get fish count and average weigh through API? | Can you get pellet size through API? | Maximum number of meals per hour per line. | [Internal] Link to detailed documentation. |
---|---|---|---|---|---|---|---|---|---|---|
Fluctus AS | Fluctus |
| Fluctus version 6.9.5.8 and newer has demonstrated satisfactory uptime.20s (140s in total) | 18 meals (200s every in total) / hour | Yes | Yes | . 20s switching time. | |||
ScaleAQ AS | FeedStation 2.0 Process API |
| Demonstrated satisfactory uptime. | Minimum and maximum intensity is driven by the amount of pellet per kilo.30s (150s in total) | 17 meals (200s every in total) / hour | Yes, with the additional feeding Data API. | ScaleAQ / hour. 30s switching time. | |||
AKVA Group AS | AKVA Connect 2.20 |
via Piscada | Compatible with when using Piscada OAP.30s (150s in total) | 17 meals (200s every in total) / hour. 30s switching time. | ||||||
AKVA Group AS | AKVA Connect 2.13-2.17 series | via Piscada | Compatible with when using Piscada OAP. Good trackrecord on stability. | 30s (150s in total) | 17 meals (200s every in total) / hour | No | No | . 30s switching time. |
...
System supplier | Software | Compatible | Comment | Known limitations | Swithcing time between cages | Can you get fish count and average weigh through API? | Can you get pellet size through API? | Maximum number of meals per hour per line. | [Internal] Link to detailed documentation. | |
AKVA Group AS | Observe Marlin Systems by Observe Technologies LTD | 🟡 Limited compatibility with OAP. | Compatible with Piscada OAP. Add on to AKVA connect 2.20 | You can not control blowers. | ||||||
AKVA Group AS | AKVA Connect 4.1-4.3 series |
via Piscada | In developement. | |||||||
AKVA Group AS | AKVA Control 10 | 🟡 Limited compatibility with OAP. | Proven poor stability makes us not recommend integrating with this feeding system. Can be compatible with Piscada OAP. Requires use of an “AKVA connector” license key. | Does not allow for blower control or blower readouts. Can not start blower without also dosing feed. Poor integration stability(ca 90%). | ||||||
AKVA Group AS | AKVA Control 9 | ❌ | Hardware and software upgrade required to integrate. | |||||||
Piscada | Open Aquaculture Plattform(OAP) | ❌ | Not a feeding system. Piscada is specialized in integrating industrial systems. | Yes | No | |||||
Ocea Feedstation | Unknown | 🟡 Limited compatibility with OAP. | Untested. Discontinued. Aquired by ScaleAQ. | |||||||
Vard Seaonics | Unknown | ❌ | Software developed by Seaonics AS. Open to integrating but has not done so to date. | |||||||
GMT | Steinsvik legacy | ❌ | Discontinued. Aquired by ScaleAQ. | |||||||
ScaleAQ AS | Steinsvik legacy system | 🟡 Limited compatibility with OAP. | Untested. Requires a licence from ScaleAQ. | Yes | No | |||||
AKVA Group AS | FishTalk Control | ❌ | Not a feeding system. Extensively used ERP. | |||||||
JTElectric | JTElectric | ❔ | Untested | Yes | No | |||||
Laksesystemer | Unknown | 🟡 Limited compatibility with OAP. | Untested | |||||||
Betten feeders | Unknown | 🟡 Limited compatibility with OAP. | Untested | |||||||
Huber | Unknown | ❔ | Untested |