System supplier

Software

Compatible

Type

Comment

Known limitations

Estimated Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

Fluctus AS

Fluctus

(tick)

PLC

Fluctus version 6.9.5.8 and newer has demonstrated satisfactory uptime.

18 meals/ hour. 20s switching time.

ScaleAQ AS

Process API (

FeedStation 2.0

)

Process API

(tick)

REST API

Demonstrated satisfactory uptime.

Minimum and maximum intensity is driven by the amount of pellet per kilo.

17 meals/ hour. 30s switching time.

AKVA Group AS

AKVA Connect

4.x

AKVAs future solution. Unreleased. Long delayed. SalMar said it would be delivered Q2 2021

2.13- 2.20.

(tick)

Compatible when using Piscada OAP. Demonstrated satisfactory uptime.

17 meals/ hour. 30s switching time.

Uncompatible or untested feedingsystems

...

System supplier

Software

Compatible

Comment

Known limitations

Estimated Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

AKVA Group AS

AKVA Connect

2.20

REST API

Launced Oct 2020. Used by AKVA Observe.

4.1-4.3 series

(tick)

with Piscada OAP.

In developement.

GroAqua

GroAqua

Untested.

Huber

Unknown

Untested.

AKVA Group AS

AKVA

Akva Connect 2

🟡 Full compatibility with OAP.

Made by Piscada under contract in 2015. Compatible with Piscada OAP and proven to have high uptime

Old. Requires hw upgrade to perform satisfactory. Compatible with Piscada OAP with AKVA connector.

Used with Piscada OAP by SalMar at Korsneset and Storskjæret in 2020-2021

.x with Observe Marlin Systems by Observe Technologies LTD on

Tested in 2021 and 2022 and found not workable.

Very unstable. You can not read pressure levels or control blowers.

AKVA Group AS

AKVA Control 10

No PLC. Uses relays. Possible to integrate through feed PC.

Discontinued. Proven poor stability makes us not recommend integrating with this feeding system.

Does not allow for blower control or blower readouts.

Can not start blower without also dosing feed.

Poor integration stability(ca 90%).

AKVA Group AS

AKVA Control 9

Ancient tech

Discontinued.

Requires HW

Hardware and

SW

software upgrade required to integrate.

Piscada

Open Aquaculture Plattform(OAP)

(tick)

Integration service.

Not a feeding system.

We may purchase OAP licences to integrate with Piscada.

https://piscada.com/nb/akvakultur/

Ocea

Ocea Feedstation

Unknown

Discontinued.

Aquired

Acquired by ScaleAQ.

Vard Seaonics

Unknown

Unknown

SW believed to be

Software developed by Seaonics AS. No integration known.

GMT

Steinsvik legacy

Discontinued.

Aquired

JTElectric

JTElectric

Have some code, but is perhaps not relevant anymore

Acquired by ScaleAQ.

ScaleAQ AS

Steinsvik legacy system

AKVA Group AS

FishTalk Control

Have some code, but is perhaps not relevant anymore.

Not a feeding system.

Old but extensively used ERP. Known to be hard to integrate with. https://www.akvagroup.com/programvare/fishtalk-control--

Untested. Requires a licence from ScaleAQ.

Laksesystemer

Unknown

🟡 Limited compatibility with OAP

Untested.

Betten feeders

Unknown

🟡 Limited compatibility with OAP.

Huber

Unknown

Articles

Untested.

Piscada Open Aquaculture Plattform(OAP) may be subcontracted to provide an integration layer by CageEye at the direction of the customer.