Follow the description for your feeding system.
How integration works
...
Sketch of feeding machinery and cages(units).
How it works:
Bluegrove deals only with cages(units in the sketch).
Bluegrove sends a signal to start feeding X kg/minute for cage Y.
It does not say which pipe to use.
Everything on the barge is handled by the feeding system, not Bluegrove.
When speaking with feeding system, Bluegrove refers to cages by their “External id”.
Info |
---|
Bluegrove tech-support is happy to help you. They can be reached on: +47 72 90 92 22 |
Follow the description for your feeding system.
https://docs.google.com/presentation/d/1iqE9p6DOP7yTZ6GET3weHWKMFQZ_O3CSV0ZNmPhmOiQ/edit#slide=id.ge281d6cf07_0_0 (unsure what you meant Martin, so made a rough draft
1. AKVA Group
Info |
---|
Contact person in AKVA Group |
...
Link to AKVA group user manuals.
https://www.akvagroup.com/brukerh%C3%A5ndb%C3%B8ker
a. AKVA Control 10
...
Contact your feeding system or check user manual to adjust settings
...
If you experience any problems, do not hesitate to contact support.
...
- Uses Piscada OAP.
Update the settings in AKVA Control 10 according to the user manual.
Check if feed is coming out in the correct cage. If the feed comes out in the wrong cage, please call Bluegrove tech support on +47 72 90 92 22. They will follow the procedure for changing pipe in Piscada OAP.
b. AKVA Connect 2.13-2.17 - Uses Piscada OAP.
Update the settings in AKVA Connect according to the user manual.
...
Check if feed is coming out in the correct cage. If the feed comes out in the wrong cage, please call Bluegrove tech support on +47 72 90 92 22. They will follow the procedure for changing pipe
...
2. Fluctus - All versions
Info |
---|
Contact informationRaymond Horne - Service technician / Project manager |
First contact your feeding system or check the manual for how to change feeding pipes/silos.
...
Update the settings in Fluctus according to the user manual. No further steps required.
3. ScaleAQ - All versions
Info |
---|
Contact information
|
First contact your feeding system or check the manual for how to change feeding pipes/silos.
...
Update the settings in Feedstation according to the user manual. No further steps required.
4. Piscada Open Aquaculture Platform (OAP) - All versions
If external cage ID are unchanged, we don’t have to change anything on our side. It will continue to control the feeding on cage level, not the pipe.
Bluegrove tech-support calls Piscada
Inform Piscada about new feeding-line ID
Await feedback from Piscada
Test-meal with feeder, to ensure functionality.
Info |
---|
Contact informationPhone number: +47 74 38 83 00 |
First contact your feeding system or check the manual for how to change feeding pipes/silos.
If Feeding Assistant doesn't work after this
...
Contact Bluegrove tech-support
...
Tech-support will check our systems
...
Check to see if external cage ID is unchanged, if so: no action is required.
If the external id is changed:
Inform Piscada about new feeding-line ID
When Piscada has reconfigured the line, do a test meal.