Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

System supplier

Software

Compatible

Comment

Known limitations

Estimated Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

Fluctus AS

Fluctus

(tick)

Fluctus version 6.9.5.8 and newer has demonstrated satisfactory uptime.

18 meals/ hour. 20s switching time.

ScaleAQ AS

FeedStation 2.0 Process API

(tick)

Demonstrated satisfactory uptime.

Minimum and maximum intensity is driven by the amount of pellet per kilo.

17 meals/ hour. 30s switching time.

AKVA Group AS

AKVA Connect 2.20

(tick)

Compatible when using Piscada OAP.

17 meals/ hour. 30s switching time.

AKVA Group AS

AKVA Connect 2.13- 2.17 series20.

(tick)

Compatible when using Piscada OAP. Demonstrated satisfactory uptime.

17 meals/ hour. 30s switching time.

Uncompatible or untested feedingsystems

System supplier

Software

Compatible

Comment

Known limitations

Estimated Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

AKVA Group AS

Observe Marlin Systems by Observe Technologies LTD

🟡 Limited compatibility with OAP.

Compatible with Piscada OAP. Add on to AKVA connect 2.20

You can not control blowersAKVA Connect 4.1-4.3 series

(tick)

with Piscada OAP.

In developement.

GroAqua

GroAqua

Untested.

Huber

Unknown

Untested.

AKVA Group ASAKVA

Akva Connect 4.1-4.3 series

(tick)

via Piscada

In developement2.x with Observe Marlin Systems by Observe Technologies LTD on

Tested in 2021 and 2022 and found not workable.

Very unstable. You can not read pressure levels or control blowers.

AKVA Group AS

AKVA Control 10

🟡 Limited compatibility with OAP.

Discontinued. Proven poor stability makes us not recommend integrating with this feeding system. Can be compatible with Piscada OAP. Requires use of an “AKVA connector” license key.

Does not allow for blower control or blower readouts.

Can not start blower without also dosing feed.

Poor integration stability(ca 90%).

AKVA Group AS

AKVA Control 9

Discontinued. Hardware and software upgrade required to integrate.

Piscada

Open Aquaculture Plattform(OAP)

Not a feeding system. Piscada is specialized in integrating industrial systems.

Ocea Feedstation

Unknown

🟡 Limited compatibility with OAP.

Untested.

Discontinued. Aquired Acquired by ScaleAQ.

Vard Seaonics

Unknown

Software developed by Seaonics AS. Open to integrating but has not done so to dateNo integration known.

GMT

Steinsvik legacy

Discontinued. Aquired Acquired by ScaleAQ.

ScaleAQ AS

Steinsvik legacy system

🟡 Limited compatibility with OAP.

Untested. Requires a licence from ScaleAQ.

AKVA Group AS

FishTalk Control

Not a feeding system. Extensively used ERP.

JTElectric

JTElectric

Untested

Laksesystemer

Unknown

🟡 Limited compatibility with OAP.

Untested

Laksesystemer

Unknown

Untested.

Betten feeders

Unknown

🟡 Limited compatibility with OAP.

Untested

Huber

Unknown

Untested.

Piscada Open Aquaculture Plattform(OAP) may be subcontracted to provide an integration layer by CageEye at the direction of the customer.