CageEye uses regular ethernet on the cage. The CageEye cabinet can be connected to any ethernet with dhcpDHCP.
Step 1. Verify that the RJ45 cable/socket have fully working network.
If there is an EAP on site:
Switch ethernet cables going into the EAP, if the EAP works the cable is ok.
If no EAP is present, you can try any other equipment that uses ethernet, for example an IP-camera or laptop, if the device gets working network, the connection is ok.
Step 2. Connect to cage network.
1. Connecting to Akvasmart IP CAP / DIGITAL CAP
...
At the customers instruction, CageEye can use the Ethernet connection in the CAP to facilitate communication between the cage and the barge.
1.2 Connect to CAP
CageEye provides the cable from the CageEye cabinet to the CAP.
Alternative | From CAP | Middle piece | To CageEye cabinet |
---|---|---|---|
1. | Cable from cap with Connector:VS-08-RJ45-5-Q/IP67-BK (1658493) With Protective cap: S-SCRJ-PC (Art no: 1653757) | Cable to CageEye with Connector:VS-08-RJ45-5-Q/IP67-BK (1658493) With Protective cap: S-SCRJ-PC (Art no: 1653757) | |
Alternatives with re-terminating the ethernet cable from the CAP | |||
Female connector: Binder RD24 (Art no: 99 4218 110 07) | - | Male connector: Binder RD24(Art no: 99 4217 110 07) | |
3 | Female connector: | - | Male connector: Amphenol Ecomate (Art no: C016 30H006 110 12) |
...
View file | ||
---|---|---|
|
View file | ||
---|---|---|
|
Troubleshooting
Symptom | Cause | Remedy |
---|---|---|
|
| |
Appendix
5. The CageEye Cage Cabinet interface
...
Cat cable termination | |||
---|---|---|---|
Connector Pin # | Wire Color | Rj45 pin number | Cable Pair(if colors differ) |
1 | White/Orange | 1 | 2 |
2 | Orange | 2 | 2 |
3 | White/Green | 3 | 3 |
4 | Green | 6 | 3 |
5 | White/Brown AND Brown | 7-8 | 4 |
6 | White/Blue AND Blue | 4-5 | 1 |
Earth | Shield |
Troubleshooting
...
Symptom
...
Cause
...
Remedy
...
Loose connector casing.
To small cable used.
...
If wire does not have water in it or corrosion damage: You can replace the connector.
If too small wire is used: replace wire.
...
AKVA Group Winch cable pinout on Amphenol Ecomate.
...