Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

CageEye uses regular ethernet on the cage. The CageEye cabinet can be connected to any ethernet with dhcpDHCP.

Step 1. Verify that the RJ45 cable/socket have fully working network.

  1. If there is an EAP on site:

    1. Switch ethernet cables going into the EAP, if the EAP works the cable is ok.

  2. If no EAP is present, you can try any other equipment that uses ethernet, for example an IP-camera or laptop, if the device gets working network, the connection is ok.

Step 2. Connect to cage network.

1. Connecting to Akvasmart IP CAP / DIGITAL CAP

...

At the customers instruction, CageEye can use the Ethernet connection in the CAP to facilitate communication between the cage and the barge.

1.2 Connect to CAP

CageEye provides the cable from the CageEye cabinet to the CAP.

Alternative

From CAP

Middle piece

To CageEye cabinet

1.

bilde-20240920-105525.png

Cable from cap with Connector:VS-08-RJ45-5-Q/IP67-BK (1658493)

Product photo Protective cover VS-SCRJ-PC

With Protective cap: S-SCRJ-PC (Art no: 1653757)

image-20240926-193544.png

Phoenix Contact VS-08-KU-IP67 Series RJ45 Coupler, Cat5e

bilde-20240920-105525.png

Cable to CageEye with Connector:VS-08-RJ45-5-Q/IP67-BK (1658493)

Product photo Protective cover VS-SCRJ-PC

With Protective cap: S-SCRJ-PC (Art no: 1653757)

Alternatives with re-terminating the ethernet cable from the CAP
If damaged, the life of the cable can be extended by replacing the connector.

image-20240924-122438.png

Female connector: Binder RD24 (Art no: 99 4218 110 07)

image-20240924-122220.png

With: Binder Protective Cap (Art no: 08 2300 000 000)

-

bilde-20240923-080240.png

Male connector: Binder RD24(Art no: 99 4217 110 07)

image-20240924-121527.png

With: Binder Protective Cap (Art no: 08 2299 000 000)

3

Female connector:

-

C016 30H006 110 12

Male connector: Amphenol Ecomate (Art no: C016 30H006 110 12)

C016 00U000 010 12

With: Protective Cap (Art no: C016 00U000 010 12)

...

View file
nameUK Akvasmart CAP Installation and maintenance manual.pdf
View file
nameNO Cage Access Point BrukerhÄndbok Rev A 2021_AKVA group.pdf

Troubleshooting

Symptom

Cause

Remedy

bilde-20240924-152357.pngImage Added

  1. Loose connector casing.

  2. To small cable used.

  1. If wire does not have water in it or corrosion damage: You can replace the connector.

  2. If too small wire is used: replace wire.

Appendix

5. The CageEye Cage Cabinet interface

...

Cat cable termination

Connector Pin #

image-20240923-151344.png

Wire Color

Rj45 pin number

bilde-20240923-080825.png

Cable Pair(if colors differ)

1

White/Orange

1

2

2

Orange

2

2

3

White/Green

3

3

4

Green

6

3

5

White/Brown AND Brown

7-8

4

6

White/Blue AND Blue

4-5

1

Earth

Shield

Troubleshooting

...

Symptom

...

Cause

...

Remedy

bilde-20240924-152357.pngImage Removed

...

  1. Loose connector casing.

  2. To small cable used.

...

  1. If wire does not have water in it or corrosion damage: You can replace the connector.

  2. If too small wire is used: replace wire.

...

AKVA Group Winch cable pinout on Amphenol Ecomate.

...