System supplier | Software | Compatible | Comment | Known limitations |
---|
Time between the meals
Time from the last pellet is dosed in one cage; until it doses the first pellet into the next cage. Default pre-/post-flushing - 120 seconds
Can you get fish count and average weigh through API?
Can you get pellet size through API?
Estimated Maximum number of meals per hour per line. | |||
---|---|---|---|
Fluctus AS | Fluctus |
| Fluctus version 6.9.5.8 and newer has demonstrated satisfactory uptime. |
20s (140s in total)
Yes
Yes
18 meals/ hour. 20s switching time. | ||||
ScaleAQ AS | FeedStation 2.0 Process API |
| Demonstrated satisfactory uptime. | Minimum and maximum intensity is driven by the amount of pellet per kilo. |
30s (150s in total)
Yes, with the additional feeding Data API.
AKVA Group AS
AKVA Connect 2.20
via Piscada
Compatible with Piscada OAP.
30s (150s in total)
17 meals/ hour. 30s switching time. | |
AKVA Group AS | AKVA Connect 2.13- 2.20. |
Compatible |
when using Piscada OAP. |
Demonstrated satisfactory uptime. |
30s (150s in total)
No
No
17 meals/ hour. 30s switching time. |
Uncompatible or untested feedingsystems
System supplier | Software | Compatible | Comment | Known limitations |
Swithcing time between cages
Can you get fish count and average weigh through API?
Can you get pellet size through API?
Estimated Maximum number of meals per hour per line. | |
AKVA Group AS |
Observe Marlin Systems by Observe Technologies LTD
🟡 Limited compatibility with OAP.
AKVA Connect 4.1-4.3 series |
with Piscada OAP. |
You can not control blowers.
In developement. | |||||
GroAqua | GroAqua | ❔ | Untested. | ||
Huber | Unknown | ❔ | Untested. | ||
AKVA Group AS |
Akva Connect |
via Piscada
In developement.
2.x with Observe Marlin Systems by Observe Technologies LTD on | ❌ | Tested in 2021 and 2022 and found not workable. | Very unstable. You can not read pressure levels or control blowers. | |
AKVA Group AS | AKVA Control 10 |
🟡 Limited compatibility with OAP.
❌ | Discontinued. Proven poor stability makes us not recommend integrating with this feeding system |
. |
Does not allow for blower control or blower readouts. Can not start blower without also dosing feed. Poor integration stability(ca 90%). |
AKVA Group AS | AKVA Control 9 | ❌ | Discontinued. Hardware and software upgrade required to integrate |
Piscada
Open Aquaculture Plattform(OAP)
❌
. |
Yes
No
Ocea Feedstation | Unknown |
🟡 Limited compatibility with OAP.
❌ | Discontinued. |
Acquired by ScaleAQ. | |||
Vard Seaonics | Unknown | ❌ | Software developed by Seaonics AS. |
No integration known. | |||
GMT | Steinsvik legacy | ❌ | Discontinued. |
Acquired by ScaleAQ. | ||
ScaleAQ AS | Steinsvik legacy system |
❌ | Untested. Requires a licence from ScaleAQ. |
Yes
No
AKVA Group AS
FishTalk Control
❌
Not a feeding system. Extensively used ERP.
JTElectric
JTElectric
❔
Untested
Yes
No
Laksesystemer
Unknown
🟡 Limited compatibility with OAP.
Untested
Laksesystemer | Unknown | ❌ | Untested. | ||
Betten feeders | Unknown |
❌ | Untested |
Huber
Unknown
❔
. |
Piscada Open Aquaculture Plattform(OAP) may be subcontracted to provide an integration layer by CageEye at the direction of the customer.