System supplier | Software | Compatible | Comment | Known limitations |
---|
Shortest meal time
Time from the last pellet is dosed in one cage; until it doses the first pellet into the next cage. Includes 180 sec flushing.
Can you get fish count and average weigh through API?
Can you get pellet size through API?
Estimated Maximum number of meals per hour per line. | |||
---|---|---|---|
Fluctus AS | Fluctus |
| Fluctus version 6.9.5.8 and newer has demonstrated satisfactory uptime. |
Yes
Yes
18 meals/ hour. 20s switching time. | ||||
ScaleAQ AS | FeedStation 2.0 Process API |
| Demonstrated satisfactory uptime. | Minimum and maximum intensity is driven by the amount of pellet per kilo. |
Yes, with the additional feeding Data API.
AKVA Group AS
AKVA Connect 2.20
via Piscada
Compatible with Piscada OAP.
17 meals/ hour. 30s switching time. | |
AKVA Group AS | AKVA Connect 2.13- 2.20. |
|
via Piscada
Compatible |
when using Piscada OAP. |
Demonstrated satisfactory uptime. |
No
No
17 meals/ hour. 30s switching time. |
Uncompatible or untested feedingsystems
System supplier | Software | Compatible | Comment | Known limitations |
Swithcing time between cages
Can you get fish count and average weigh through API?
Can you get pellet size through API?
Estimated Maximum number of meals per hour per line. | |
AKVA Group AS |
Observe Marlin Systems by Observe Technologies LTD
🟡 Limited compatibility with OAP.
AKVA Connect 4.1-4.3 series |
with Piscada OAP. |
You can not control blowers.
In developement. | |||||
GroAqua | GroAqua | ❔ | Untested. | ||
Huber | Unknown | ❔ | Untested. | ||
AKVA Group AS |
Akva Connect |
via Piscada
In developement.
2.x with Observe Marlin Systems by Observe Technologies LTD on | ❌ | Tested in 2021 and 2022 and found not workable. | Very unstable. You can not read pressure levels or control blowers. | |
AKVA Group AS | AKVA Control 10 |
🟡 Limited compatibility with OAP.
❌ | Discontinued. Proven poor stability makes us not recommend integrating with this feeding system |
. | Does not allow for blower control or blower readouts. Can not start blower without also dosing feed. Poor integration stability(ca 90%). |
AKVA Group AS | AKVA Control 9 | ❌ | Discontinued. Hardware and software upgrade required to integrate. |
Open Aquaculture Plattform(OAP)
❌
Not a feeding system. Piscada is specialized in integrating industrial systems.
Yes
No
Ocea Feedstation | Unknown |
🟡 Limited compatibility with OAP.
❌ | Discontinued. |
Acquired by ScaleAQ. | |||
Vard Seaonics | Unknown | ❌ | Software developed by Seaonics AS. |
No integration known. | |||
GMT | Steinsvik legacy | ❌ | Discontinued. |
Acquired by ScaleAQ. | ||
ScaleAQ AS | Steinsvik legacy system |
❌ | Untested. Requires a licence from ScaleAQ. |
Yes
No
AKVA Group AS
FishTalk Control
❌
Not a feeding system. Extensively used ERP.
JTElectric
JTElectric
❔
Untested
Yes
No
Laksesystemer
Unknown
🟡 Limited compatibility with OAP.
Untested
Laksesystemer | Unknown | ❌ | Untested. | ||
Betten feeders | Unknown |
❌ | Untested |
Huber
Unknown
❔
. |
Piscada Open Aquaculture Plattform(OAP) may be subcontracted to provide an integration layer by CageEye at the direction of the customer.