Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

System supplier

Software

Compatible

Comment

Known limitations

Smallest possible intensity

Can we get fish count and avg weigh?

Can we get pellet size?

Detailed information

Estimated Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

Fluctus AS

Fluctus

(tick)

Fluctus version 6.9.5.8 and newer has demonstrated satisfactory uptime.

Yes

Yes

Fluctus

18 meals/ hour. 20s switching time.

ScaleAQ AS

FeedStation 2.0 Process API

(tick)

Some minor bugs

Demonstrated satisfactory uptime.

Min

Minimum and

max

maximum intensity is driven by the amount of pellet per kilo.

Yes. With: Feeding Data API

ScaleAQ

Observe Technologies LTD

Observe Marlin Systems

(tick)

via Piscada

Add on to AKVA connect 2.x

Unable to control blowers.

/wiki/spaces/TRB/pages/937230351

AKVA Group AS

AKVA Connect 2.20

(tick)

via Piscada

Compatible with Piscada OAP.

/wiki/spaces/TRB/pages/637108308

17 meals/ hour. 30s switching time.

AKVA Group AS

AKVA Connect 2.13- 2.20.

17 series

(tick)

via Piscada

Compatible

with

when using Piscada OAP.

Good trackrecord on stability/wiki/spaces/TRB/pages/637108308

Demonstrated satisfactory uptime.

No

No

17 meals/ hour. 30s switching time.

Uncompatible or untested feedingsystems

System supplier

Software

Compatible

Comment

Known limitations

Smallest possible intensity

Can we get fish count and avg weigh?

Can we get pellet size?

Detailed information

Estimated Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

AKVA Group AS

AKVA Connect 4.1-4.3 series

(tick)

via

with Piscada OAP.

In developement

./wiki/spaces/TRB/pages/637108308 Can be compatible with Piscada OAP. Requires use of an “AKVA connector” license key. Poor

.

GroAqua

GroAqua

Untested.

Huber

Unknown

Untested.

AKVA Group AS

Akva Connect 2.x with Observe Marlin Systems by Observe Technologies LTD on

Tested in 2021 and 2022 and found not workable.

Very unstable. You can not read pressure levels or control blowers.

AKVA Group AS

AKVA Control 10

(tick)

via Piscada

Discontinued. Proven poor stability makes us not

reccomend

recommend integrating with this feeding system.

Does not allow for blower control or blower readouts.

Can not start blower without also dosing feed.

Poor integration stability(ca 90%).

/wiki/spaces/TRB/pages/637108308

AKVA Group AS

AKVA Control 9

Discontinued. Hardware and software upgrade required to integrate

.

/wiki/spaces/TRB/pages/637108308

Piscada

Open Aquaculture Plattform(OAP)

(tick)

Not a feeding system

.

Piscada is specialized in integrating industrial systems.

Yes

No

Piscada Untested.

Ocea Feedstation

Unknown

🟡 Limited compatibility with OAP.

Discontinued.

Aquired

Acquired by ScaleAQ.

Vard Seaonics

Unknown

Software developed by Seaonics AS.

Open to integrating but has not done so to date

No integration known.

GMT

Steinsvik legacy

Discontinued.

Aquired

Acquired by ScaleAQ.

ScaleAQ AS

Steinsvik legacy system

🟡 Limited compatibility with OAP.

Untested. Requires a licence from ScaleAQ.

Yes

Laksesystemer

No

AKVA Group AS

FishTalk Control

Not a feeding system. Extensively used ERP.

JTElectric

JTElectric

Untested

Yes

No

Laksesystemer

Unknown

🟡 Limited compatibility with OAP.

Untested

Unknown

Untested.

Betten feeders

Unknown

🟡 Limited compatibility with OAP.

Untested

Huber

Unknown

Untested

Articles

...

.

Piscada Open Aquaculture Plattform(OAP) may be subcontracted to provide an integration layer by CageEye at the direction of the customer.