System supplier | Software | Compatible |
---|
Type
Comment | Known limitations |
---|
Smallest possible intensity
Can we get fish count and avg weigh?
Can we get pellet size?
Detailed information
Estimated Maximum number of meals per hour per line. | |||
---|---|---|---|
Fluctus AS | Fluctus |
| Fluctus version 6.9.5.8 and newer has demonstrated satisfactory uptime. |
Yes
Yes
18 meals/ hour. 20s switching time. | ||
ScaleAQ AS | FeedStation 2.0 Process API |
|
REST API
Demonstrated satisfactory uptime. |
Minimum and |
maximum intensity is driven by the amount of pellet per kilo. |
Yes. With: Feeding Data API
17 meals/ hour. 30s switching time. | |
AKVA Group AS | AKVA Connect |
2. |
13- |
2.20. |
|
via Piscada
Untested. In developement.
Observe Technologies LTD
Observe Marlin Systems
via Piscada
REST API
Untested. Add on to AKVA connect 2.x
Lacks blower control.
Compatible when using Piscada OAP. Demonstrated satisfactory uptime. | 17 meals/ hour. 30s switching time. |
Uncompatible or untested feedingsystems
System supplier | Software | Compatible | Comment | Known limitations | Estimated Maximum number of meals per hour per line. |
AKVA Group AS | AKVA Connect |
4.1-4.3 series |
|
via Piscada
REST API
Untested. Unsure if this exists? Launched by AKVA inCompatible according to Tore Obrestad and Jørn Torsvik at AKVA. AKVA reps tells us that 2.20 will be used globally for quite some time until the 4.x series is ready.
AKVA Group AS
AKVA Connect 2.13-2.17 series
Full compatibility with OAP /
via Piscada
OAP
Compatible with Piscada OAP. Good trackrecord on stability.
No
No
with Piscada OAP. | In developement. | ||||
GroAqua | GroAqua | ❔ | Untested. | ||
Huber | Unknown | ❔ | Untested. | ||
AKVA Group AS | Akva Connect 2.x with Observe Marlin Systems by Observe Technologies LTD on | ❌ | Tested in 2021 and 2022 and found not workable. | Very unstable. You can not read pressure levels or control blowers. | |
AKVA Group AS | AKVA Control 10 |
via Piscada
OAP
❌ | Discontinued. Proven poor stability makes us not recommend integrating with this feeding system. | Does not allow for blower control or blower readouts. Can not start blower without also dosing feed. |
Poor integration stability |
(ca 90%). | |||
AKVA Group AS | AKVA Control 9 | ❌ | Discontinued. Hardware and software upgrade required to integrate |
Piscada
Open Aquaculture Plattform(OAP)
Integration service.
. |
https://piscada.com/nb/akvakultur/
Yes
No
Ocea Feedstation | Unknown |
🟡 Limited compatibility with OAP.
❌ | Discontinued. |
Acquired by ScaleAQ. | |||
Vard Seaonics | Unknown | ❌ | Software developed by Seaonics AS. |
No integration known. | |||
GMT | Steinsvik legacy | ❌ | Discontinued. |
Acquired by ScaleAQ. | ||
ScaleAQ AS | Steinsvik legacy system |
❌ | Untested. Requires a licence from ScaleAQ. |
Yes
No
AKVA Group AS
Laksesystemer | Unknown | ❌ |
Untested. |
Betten feeders |
Unknown |
❔
Yes
No
Laksesystemer
Unknown
🟡 Limited compatibility with OAP.
Betten feeders
Unknown
🟡 Limited compatibility with OAP.
Huber
Unknown
❔
Articles
...
❌ | Untested. |
Piscada Open Aquaculture Plattform(OAP) may be subcontracted to provide an integration layer by CageEye at the direction of the customer.