System supplier

Software

Compatible

Type

Comment

Known limitations

Smallest possible intensity

Can we get fish count and avg weigh?

Can we get pellet size?

Detailed information

Estimated Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

Fluctus AS

Fluctus

(tick)

Fluctus version 6.9.5.8

preferred.

Yes

Fluctus Min and max

and newer has demonstrated satisfactory uptime.

18 meals/ hour. 20s switching time.

ScaleAQ AS

FeedStation 2.0 Process API

(tick)

REST API

ScaleAQ

Demonstrated satisfactory uptime.

Minimum and maximum intensity is driven by the amount of pellet per kilo.

Yes. With: Feeding Data API

17 meals/ hour. 30s switching time.

AKVA Group AS

AKVA Connect

4

2.

1

13-

4

2.20.

3 series

Untested. The new solution developed by AKVA.

/wiki/spaces/TRB/pages/637108308

AKVA Group AS

AKVA Connect 2.20

(tick)

REST API

Untested. Compatible according to Tore Obrestad and Jørn Torsvik at AKVA. AKVA reps tells us that 2.20 will be used globally for quite some time until the 4.x series is ready.

/wiki/spaces/TRB/pages/637108308

(tick)

Compatible when using Piscada OAP. Demonstrated satisfactory uptime.

17 meals/ hour. 30s switching time.

Uncompatible or untested feedingsystems

System supplier

Software

Compatible

Comment

Known limitations

Estimated Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

AKVA Group AS

AKVA Connect

2

4.

13

1-

2

4.

17

3 series

(tick)

Full compatibility

with Piscada OAP

.

OAP

Compatible with Piscada OAP. Good trackrecord on stability.

/wiki/spaces/TRB/pages/637108308 Compatible with Piscada OAP. Requires use of an “AKVA connector” license key

.

In developement.

GroAqua

GroAqua

Untested.

Huber

Unknown

Untested.

AKVA Group AS

Akva Connect 2.x with Observe Marlin Systems by Observe Technologies LTD on

Tested in 2021 and 2022 and found not workable.

Very unstable. You can not read pressure levels or control blowers.

AKVA Group AS

AKVA Control 10

🟡 Limited compatibility with OAP.

OAP.

Discontinued. Proven poor stability makes us not recommend integrating with this feeding system.

Does not allow for blower control or blower readouts.

Can not start blower without also dosing feed.

Low

Poor integration stability

./wiki/spaces/TRB/pages/637108308

(ca 90%).

AKVA Group AS

AKVA Control 9

Discontinued. Hardware and software upgrade required to integrate

.

/wiki/spaces/TRB/pages/637108308

Piscada

Open Aquaculture Plattform(OAP)

(tick)

Integration service.

Not a feeding system. Piscada is specialized in integrating industrial systems. We can buy integration as a service from Piscada.

https://piscada

.

com/nb/akvakultur/Piscada Untested.

Ocea Feedstation

Unknown

🟡 Limited compatibility with OAP.

Discontinued.

Aquired

Acquired by ScaleAQ.

Vard Seaonics

Unknown

Software developed by Seaonics AS.

Open to integrating but has not done so to date

No integration known.

GMT

Steinsvik legacy

Discontinued.

Aquired

Acquired by ScaleAQ.

ScaleAQ AS

Steinsvik legacy system

🟡 Limited compatibility with OAP.

Untested. Requires a licence from ScaleAQ.

AKVA Group AS

FishTalk Control

Laksesystemer

Unknown

Not a feeding system. Extensively used ERP.

JTElectric

JTElectric

Laksesystemer

Unknown

🟡 Limited compatibility with OAP.

Betten feeders

Unknown

🟡 Limited compatibility with OAP.

Huber

Unknown

Articles

...

Untested.

Betten feeders

Unknown

Untested.

Piscada Open Aquaculture Plattform(OAP) may be subcontracted to provide an integration layer by CageEye at the direction of the customer.