Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

System supplier

Software

Compatible

Type

Comment

Known limitations

Estimated Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

Fluctus AS

Fluctus

(tick)

Fluctus version 6.9.5.8

(tick)

and newer has demonstrated satisfactory uptime.

18 meals/ hour. 20s switching time.

ScaleAQ AS

Process API (

FeedStation 2.0

)

Process API

(tick)

REST API

Demonstrated satisfactory uptime.

Minimum and maximum intensity is driven by the amount of pellet per kilo.

17 meals/ hour. 30s switching time.

AKVA Group AS

AKVA Connect

4.1

The current solution offered by AKVA. Very few systems delivered

2.13- 2.20.

(tick)

Compatible when using Piscada OAP. Demonstrated satisfactory uptime.

17 meals/ hour. 30s switching time.

Uncompatible or untested feedingsystems

System supplier

Software

Compatible

Comment

Known limitations

Estimated Maximum number of meals per hour per line.
Meals are divided between the cages on the line. We assume: 60s pre-flush, 60s meals, 60s post-flush and a variable switching time.

AKVA Group AS

AKVA Connect

2.20

REST API

Launched Oct 2020. Should be compatible with our requirements according to Tore Obrestad and Jørn Torsvik at AKVA

4.1-4.3 series

(tick)

with Piscada OAP.

In developement.

GroAqua

GroAqua

Untested.

Huber

Unknown

Untested.

AKVA Group AS

AKVA

Akva Connect 2.x

🟡 Full compatibility with OAP.

Compatible with Piscada OAP and proven to have high uptime

with Observe Marlin Systems by Observe Technologies LTD on

Tested in 2021 and 2022 and found not workable.

Very unstable. You can not read pressure levels or control blowers.

AKVA Group AS

AKVA Control 10

Possible to integrate through feed PC.

Requires hardware upgrade to AKVA connect 2.20 perform satisfactorily. Compatible when used with Piscada OAP but requires use of an “AKVA connector” license key

Discontinued. Proven poor stability makes us not recommend integrating with this feeding system.

Does not allow for blower control or blower readouts.

Can not start blower without also dosing feed.

Low

Poor integration stability(ca 90%).

AKVA Group AS

AKVA Control 9

HW

Discontinued. Hardware and

SW upgrade required to integrate.

Piscada

Open Aquaculture Plattform(OAP)

(tick)

Integration service.

Not a feeding system.

We may purchase OAP licences to integrate with Piscada.

https://piscada.com/nb/akvakultur/

Ocea

software upgrade required to integrate.

Ocea Feedstation

Unknown

Discontinued.

Aquired

Acquired by ScaleAQ.

Vard Seaonics

Unknown

SW believed to be

Software developed by Seaonics AS. No integration known.

GMT

Steinsvik legacy

Discontinued.

Aquired ❔

Acquired by ScaleAQ.

ScaleAQ AS

Steinsvik legacy system

AKVA Group AS

FishTalk Control

Not a feeding system. Extensively used ERP. Hard to integrate with.

JTElectric

JTElectric

Untested. Requires a licence from ScaleAQ.

Laksesystemer

Unknown

🟡 Limited compatibility with OAP

Untested.

Betten feeders

Unknown

🟡 Limited compatibility with OAP.

Huber

Unknown

Articles

...

Untested.

Piscada Open Aquaculture Plattform(OAP) may be subcontracted to provide an integration layer by CageEye at the direction of the customer.