  • Click anywhere over the line from the desired cage to open the control menu > click on ‘'turn off EF and continue feeding from Akva/Fluctus/Scale’' Ömer: do we really need the exact feeding system name? If we need the exact name, will follow up on the existing card Marina suggestion: have ‘monitoring mode’ words on UI TBD with Nikita

By changing from autonomous to monitoring mode while feeding, the cage continues on the current state andyou will need to take control from the feeding system at the barge. When entering this mode no automatic changes will be done by EF and you have full control from your local feeding system. This meal will be considered ended in EF UI.

...

4. Troubleshooting

4.1 Common issues

  • EF pages are not loading. Check if

    • There is internet at the barge (Martin Munkeby is this needed?)

    • CageEye server is powered and online

  • Planner:

    • I’m not able to approve my plan for tomorrow. Check if:

      • The settings for ‘'Workday start/end’' are correct and not preventing the meals to be distributed.

      • All cages that will be fed have at least one meal.

    • On settings: I can’t increase the minimum intensity for a cage. Check if:

      • Maximum intensity is above minimum desired intensity.

      • Minimum intensity is below maximum desired intesity.

  • Execution:

    • Feed not coming out. Check if:

      • The correct silo is assigned to the cage.

      • There are any blockages on the silo/screw/feeding hose/spreader top.

      • Power is connected.

    • The meal did not start. Check if:

      • The meal is in fact planned to start now.

      • The line is active/enabled* on the feeding program at the barge

      • The cage is not in Monitoring Mode, Manual Mode or Service Mode on EF UI

    • The meal is stopping on EF before I want. Check if:

      • The maximum amount allowed to feed on the Planner was not too low, preventing the meal from continuing.

      • Timeout: The estimated meal time on Execution reached it’s maximum for that meal.

...