System supplier | Software | Compatible | Type | Comment | Known limitations | Smallest possible intensity | Can we get fish count and avg weigh? | Can we get pellet size? | Detailed information |
---|---|---|---|---|---|---|---|---|---|
Fluctus AS | Fluctus |
| Fluctus version 6.9.5.8 and newer has demonstrated satisfactory uptime. | Yes | Yes | ||||
ScaleAQ AS | FeedStation 2.0 Process API |
| REST API | Some minor bugs. | Min and max intensity is driven by the amount of pellet per kilo. | Yes. With: Feeding Data API | |||
Observe Technologies LTD | Observe Marlin Systems |
via Piscada REST API | Add on to AKVA connect 2.x | Unable to control blowers. | |||||
AKVA Group AS | AKVA Connect 2.20 |
via Piscada | REST API | Compatible with Piscada OAP. | |||||
AKVA Group AS | AKVA Connect 2.13-2.17 series | via Piscada REST API | Compatible with Piscada OAP. Good trackrecord on stability. | No | No |
...
System supplier | Software | CompatibleType | Comment | Known limitations | Smallest possible intensity | Can we get fish count and avg weigh? | Can we get pellet size? | Detailed information |
AKVA Group AS | AKVA Connect 4.1-4.3 series |
via Piscada | In developement. | |||||
AKVA Group AS | AKVA Control 10 |
via Piscada OAP | Can be compatible with Piscada OAP. Requires use of an “AKVA connector” license key. Poor stability makes us not reccomend integrating with this feeding system. | Does not allow for blower control or blower readouts. Can not start blower without also dosing feed. Poor integration stability(ca 90%). | ||||
AKVA Group AS | AKVA Control 9 | ❌ | Hardware and software upgrade required to integrate. | |||||
Piscada | Open Aquaculture Plattform(OAP) | Integration service. | Not a feeding system. Piscada is specialized in integrating industrial systems. | Yes | No | |||
Ocea Feedstation | Unknown | 🟡 Limited compatibility with OAP. | Untested. Discontinued. Aquired by ScaleAQ. | |||||
Vard Seaonics | Unknown | ❌ | Software developed by Seaonics AS. Open to integrating but has not done so to date. | |||||
GMT | Steinsvik legacy | ❌ | Discontinued. Aquired by ScaleAQ. | |||||
ScaleAQ AS | Steinsvik legacy system | 🟡 Limited compatibility with OAP. | Untested. Requires a licence from ScaleAQ. | Yes | No | |||
AKVA Group AS | FishTalk Control | ❌ | Not a feeding system. Extensively used ERP. | |||||
JTElectric | JTElectric | ❔ | Untested | Yes | No | |||
Laksesystemer | Unknown | 🟡 Limited compatibility with OAP. | Untested | |||||
Betten feeders | Unknown | 🟡 Limited compatibility with OAP. | Untested | |||||
Huber | Unknown | ❔ | Untested |
...